Structural Considerations for Pumping Station Construction

26 April 2023

This standard requires skilled people to design and build pumping stations. This standard describes wastewater pump station planning and design. Since gravity cannot release liquid, larger commercial constructions generally need pump stations. These devices hold rainfall, sewage, or other wastewater. Transfer pumps at pump stations move waste for reuse or disposal.

Main Structure

The foundation, working floor, superstructure, crane runways, and discharge facilities comprise a pumping station.

Substructure

The standard pumping station substructure contains sumps and water tunnels for pump intakes. Sump floors, base slabs for water channels, outer walls, and sump separator walls make up the substructure. The sump area components form a structure from the foundation to the operational floor. The forebay area assumes a frame from the base to the top of the side walls or outside the forebay deck. For both studies, the postulated frame joint fixity must match the structural components’ behaviour under critical design loading circumstances. The intake/trashrack deck, discharge chamber, dewatering pit, and retaining wall or flood wall components must be structurally analysed in some pumping stations.

Operating Floor

Operational floors are structural. This floor bears the dead weight of the pumping and control equipment and hydraulic thrusts from pumping. Hatches, pump apertures, and other structural floor interruptions complicate the working floor design. Hydraulic, electrical, mechanical, architectural, and structural needs are coordinated to plan this floor for spans over sump walls, machinery placement, and opening size. The floor comprises beam sections and slabs around apertures and across supporting walls. The sump arrangement dictates these supporting walls and floor pumps. To find the best plant layout, mechanical, hydraulic, and structural needs are coordinated. After determining the working floor layout and loading arrangement, structural elements may be designed. The operating floor, supporting walls, and sump floor can be constructed as continuous or discrete frames. The assumptions must match the structure’s predicted behaviour under design conditions and be based on the components’ relative sizes and the plant structure’s arrangement.

Superstructure

Most pumping plants are indoors. Plant equipment and people are enclosed. This inclosure must be weatherproof and sturdy to be cost-effective. It must also resist paragraph 4-4 loading conditions. Pumping station superstructures are usually reinforced concrete, concrete masonry unit, or brick wall sections. A separate framework supports the bridge crane within brick or concrete masonry constructions. It is often economical to incorporate this framework in the structural wall and roof section to provide additional strength and support. Still, larger cranes may require separating the crane support framework from the wall sections to prevent operating forces from transmitting to the superstructure walls.

Crane Runways

The bridge crane runways can be installed on structural steel or reinforced or prestressed concrete beam sections supported by a structural steel framework, reinforced concrete column or haunch sections, or reinforced concrete ledges. The walls will only withstand crane loads in bigger sites with reinforced concrete superstructures.

Discharge Facilities

A pumping station’s protective line-discharge facilities might vary. Pumping onto open water or a discharge chamber built inside the pumping station is typical for a protection line station. This system has the least discharge pipes but the highest hydraulic loading. A discharge chamber in the pool must be gated and built for gate maintenance. Unwatering under full external hydraulic force or removing the gates for maintenance can enable this access. Non-protection line pumping stations need considerable discharge plumbing. This pipe can go over, through, or under the protective line. The coordinated plant layout, including hydraulic, mechanical, and structural aspects, must be specified before designing this pipe, its supports, gate structures, and discharge structures. Ductile iron is used for pumping station pipes and discharge piping. Low-flow gravity discharge structures are typically needed for pumping stations on or off the protection line. This structure normally has an intake headwall with bulkhead slots, a gravity discharge conduit via the protection line, a gate structure near the conduit discharge end, and a headwall and stilling structure at the conduit outfall. Several combinations of the pumping station, pump discharge system components, and low-flow discharge system components are possible. Innovative plant configurations should be carefully assessed from a construction and operations perspective throughout design and layout to ensure constructability and ease of operation and maintenance. Coordinating these distinctive traits and arrangements with higher authorities is also important.